Approved (SPF) Spray Foam Manufacturer and Type Wet
Film
Dry
Film
Coverage Rate Per Gallon IFTI ICC-ESR Evaluation
report
IFTI IAPMO Evaluation
report
SPF Manufacturer Evaluation
Report
Select
Central Urethane X-PRESS SEAL 500 18 12 89 sq ft pe gallon Update in Progress Update in Progress ESR-5113
Central Urethane X-Press Seall 500 XP 18 12 89 sq ft per gallon Update in Progress CCRR 0479

 

Approved Foam Testing Matrix For DC315
Building Code Fire Performance Requirements for SPF:  The International Building Code (IBC) mandates that SPF be separated from the interior of the building by a prescriptive 15-minute thermal barrier, or other approved covering. DC315 Carries IAPMO ER-0499 and ICC-ESR 3702 Evaluation Report confirming DC315 provides an alternative thermal barrier assembly to the prescriptive thermal barrier requirments and  all testing complies with the 2012 IBC Section 803.1.2 & 2603.10. 2012 IRC  Section  316.6.  2015  IBC  Section  803.2.1,  803.11, 2603.9 and 2015 IRC Section 316.6.  DC 315 has also been tested as an ignition barrier under AC 377 Appendix X and meets the requirements of  ICC-ES AC377 and AC456 Criteria.
Light Gold Cells are Ignition Barrier    Light Green Cells are Thermal Barrier

 

 

 

Visit our Web site www.painttoprotect.com

 

Application Guide     Ventilation Guide       Job Work Report      Job Site Label      Safety Data Sheets      Master Specification    Recommended Sprayer